LR9G630 - Schneider Electric Electronic thermal overload relay,TeSys Giga,160-630 A,class 5

Rp 11.600.000,00 Rp 15.000.000,00
23
Atau lihat kebijakan pengiriman kami

Tax included. Shipping calculated at checkout.

160 in stock
Delivery:
Estimated delivery time: 5-7 days
Returns:
Within 45 days of purchase
Sku:
1
Payment & Security
Visa Mastercard American Express PayPal Diners Club Discover

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Note: Harga Belum Termasuk PPN 11%

 

Schneider Electric LR9G630 Electronic thermal overload relay,TeSys Giga,

160-630 A,class 5E-30E,push-in control connection

Relai beban berlebih termal TeSys LR9G 630A kompatibel dengan kontaktor daya tinggi TeSys Giga, koneksi kontrol push-in. Relai ini menyediakan perlindungan ketidakseimbangan fasa, kegagalan fasa, gangguan tanah internal, dan beban fasa tunggal. Relai ini tersedia dengan opsi pengaturan ulang manual dan otomatis, serta indikator LED untuk Motor ON dan alarm pra-trip. Kelas trip dapat dipilih dari kelas 5E hingga kelas 30E untuk memenuhi berbagai kebutuhan aplikasi, mulai dari trip cepat, beban serbaguna, hingga beban inersia tinggi. Relai ini cocok untuk pemasangan independen atau pemasangan langsung dengan kontaktor LC1G. Relai ini menyediakan perlindungan IP2x pada permukaan depan dengan selubung yang sesuai dengan IEC 60529 dan VDE 0106. Relai ini dapat mencakup suhu udara sekitar operasi -25°C hingga 60°C tanpa penurunan daya hingga ketinggian 3000 m. Bersertifikasi multi standar (CE, CB, CCC, cULus, EAC, KC, RCM, Marine) dan memenuhi standar Green Premium (RoHS/Reach). Kode QR yang unik menyediakan akses cepat ke data produk lengkap.

  • Relai beban lebih elektronik dapat terintegrasi untuk perlindungan gangguan arde (suatu jalur kabel tersendiri yang dipasang pada instalasi listrik rumah menuju titik pertanahan (bumi) dan tidak menyambung secara langsung dengan kabel-kabel lainnya pada instalasi listrik tersebut), ketidakseimbangan/kegagalan fasa, dan beban fasa tunggal.
  • Referensi yang lebih sedikit dan mencakup aplikasi yang lebih luas berarti lebih mudah untuk memilih dan lebih sedikit inventaris yang perlu dibawa.
  • Rentang pengaturan yang luas dengan perlindungan canggih.
  • Fitur lengkap untuk fleksibilitas lebih.
  • Pemantauan berkelanjutan dengan indikator kesehatan dan alarm.

Fungsi utama dari LR9G630 adalah untuk melindungi motor AC berdaya tinggi dari berbagai kondisi kesalahan listrik yang dapat menyebabkan kerusakan atau kegagalan motor. Karena menggunakan teknologi elektronik, relai ini menawarkan perlindungan yang jauh lebih akurat dan dapat disesuaikan dibandingkan relai termal bimetal tradisional.

 

Spesifikasi Schneider Electric  LR9G630 Electronic thermal overload relay,TeSys Giga

Range TeSys
Product name TeSys LRG
Product or component type
Electronic thermal overload relay
Device short name LR9G
Relay application
Motor protection
Network type AC
Thermal overload class
Class 5E...30E conforming to IEC 60947-4-1
Thermal protection adjustment range 160…630 A
Network frequency 30...60 Hz
100 Hz
Overvoltage category III
Tripping threshold
1.125 +/- 0.07 In conforming to IEC 60947-4-1
Protection type
Ground fault protection - tripping time adjustment: 0…1 s - for alarm circuit conforming to IEC 60947-4-1
Ground fault protection - tripping time adjustment: 0…1 s - for alarm circuit conforming to UL 60947-4-1
Phase loss - tripping time adjustment: 0…4 s - for alarm circuit
Phase imbalance - tripping time adjustment: 0…5 s - for alarm circuit conforming to IEC 60947-4-1
Phase imbalance - tripping time adjustment: 0…5 s - for alarm circuit conforming to UL 60947-4-1
Local signalling LED
Trip indicator
Contacts type and composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A
[Uc] control circuit voltage
24...500 V AC 50/60 Hz
24...250 V DC
[Ue] rated operational voltage
1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
Reset
Automatic reset
Manual
Mechanical durability 7000 cycles
Surge withstand 4 kV
Electromagnetic compatibility
EMC immunity conforming to IEC 60947-4-1
Emission tests criteria A conforming to IEC 60947-4-1
Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3
Voltage dips and interruptions immunity test conforming to SEMI F47
Connections - terminals
Power circuit: bar - busbar cross section: 50 x 10 mm
Power circuit: lugs-ring terminals 1 300 mm²
Control circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: push-in 2 0.5…1.0 mm² with cable end
Tightening torque 58 N.m
Mounting support
Direct on contactor
Plate
Standards
EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
UL 60335-1
Product certifications
CB Scheme
CCC
cULus
UKCA
ATEX
EU-RO-MR by DNV-GL
EAC
IP degree of protection
IP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
Protective treatment TH
Ambient air temperature for operation -25…60 °C
Ambient air temperature for storage -60…80 °C
Permissible ambient air temperature around the device
-40…60 °C at Uc
Adjustment of dial setting -25…60 °C
Mechanical robustness
Vibrations 5…300 Hz 6 gn contactor open
Shocks 15 gn 11 ms contactor closed
Height 148 mm
Width 211 mm
Depth 186 mm
Net weight 2.9 kg
Colour Dark grey
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 30.000 cm
Package 1 Width 30.000 cm
Package 1 Length 40.000 cm
Package 1 Weight 4.540 kg
Vendor AMS Network
Type electricity
Sku 1
Weight 1.5 kg